Volume 37 Issue 3
Apr.  2017
Turn off MathJax
Article Contents
Jiang Meng, Guo Zhikun, Chen Wanxiang, Zou Huihui, Liang Wenguang. Mechanical properties of reactive powder concrete-filled steel tube after exposure to high temperature under impact loading[J]. Explosion And Shock Waves, 2017, 37(3): 405-414. doi: 10.11883/1001-1455(2017)03-0405-10
Citation: Jiang Meng, Guo Zhikun, Chen Wanxiang, Zou Huihui, Liang Wenguang. Mechanical properties of reactive powder concrete-filled steel tube after exposure to high temperature under impact loading[J]. Explosion And Shock Waves, 2017, 37(3): 405-414. doi: 10.11883/1001-1455(2017)03-0405-10

Mechanical properties of reactive powder concrete-filled steel tube after exposure to high temperature under impact loading

doi: 10.11883/1001-1455(2017)03-0405-10
  • Received Date: 2015-10-12
  • Rev Recd Date: 2016-01-08
  • Publish Date: 2017-05-25
  • Experiments on reactive powder concrete-filled steel tube (RPC-FST) specimens after exposure to high temperature were performed by using a split Hopkinson pressure bar (SHPB) apparatus, and the influences of strain rate effects and temperature effects on the dynamic behaviors of RPC-FST were investigated. Test results show that the RPC-FST specimens after exposure to high temperature have excellent impact-resistance, ductility and integrity. The strain rate effects of the RPC-FST specimens are weaker than those of the RPC specimens under impact loading. The peak stress of the RPC-FST specimens increases as the temperature increases, and the deformation capability and impact-resistance increase. The dynamic increase factor (DIF) increases as the temperature increases. It means that the strain rate effects of RPC-FST become more obvious after exposure to high temperature.
  • loading
  • [1]
    Tian Zhimin, Wu Ping'an, Jia Jianwei. Dynamic response of RPC-filled steel tubular columns with high load carrying capacity under axial impact loading[J]. Transactions of Tianjin University, 2008, 14(6):441-449. doi: 10.1007/s12209-008-0076-9
    [2]
    Bambach M R. Design of hollow and concrete filled steel and stainless steel tubular columns for transverse impact loads[J]. Thin-Walled Structures, 2011, 49(10):1251-1260. doi: 10.1016/j.tws.2011.05.009
    [3]
    Remennikov A M, Kong S Y, Uy B. Response of foam- and concrete-filled square steel tubes under low-velocity impact loading[J]. Journal of Performance of Constructed Facilities, 2011, 25(5):373-381. doi: 10.1061/(ASCE)CF.1943-5509.0000175
    [4]
    Yousuf M, Uy B, Tao Z, et al. Transverse impact resistance of hollow and concrete filled stainless steel columns[J]. Journal of Constructional Steel Research, 2013, 82:177-189. doi: 10.1016/j.jcsr.2013.01.005
    [5]
    Han Linhai, Hou Chuanchuan, Zhao Xiaoling, et al. Behaviour of high-strength concrete filled steel tubes under transverse impact loading[J]. Journal of Constructional Steel Research, 2014, 92(1):25-39. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=7f0b3eea375dbc763649c5047f08e777
    [6]
    Wang Rui, Han Linhai, Hou Chuanchuan. Behavior of concrete filled steel tubular (CFST) members under lateral impact: Experiment and FEA model[J]. Journal of Constructional Steel Research, 2013, 80(1):188-201. http://www.sciencedirect.com/science/article/pii/S0143974X12002106
    [7]
    何远明, 霍静思, 陈柏生.高温下钢管混凝土SHPB动态力学性能试验研究[J].工程力学, 2013, 30(1):52-58. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=QKC20132013051500003654

    He Yuanming, Huo Jingsi, Chen Baisheng. Impact tests on dynamic behavior of concrete-filled steel tube at elevated temperatures[J]. Engineering Mechanics, 2013, 30(1):52-58. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=QKC20132013051500003654
    [8]
    霍静思, 任晓虎, 肖岩.标准火灾作用下钢管混凝土短柱落锤动态冲击试验研究[J].土木工程学报, 2012, 45(4):9-20. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=QK201200684144

    Huo Jingsi, Ren Xiaohu, Xiao Yan. Impact behavior of concrete-filled steel tubular stub columns under ISO-834 standard fire[J]. China Civil Engineering Journal, 2012, 45(4):9-20. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=QK201200684144
    [9]
    霍静思, 何远明, 肖莉平, 等.高温后钢管混凝土抗多次冲击力学性能试验研究[J].湖南大学学报(自然科学版), 2012, 39(9):6-10. doi: 10.3969/j.issn.1674-2974.2012.09.002

    Huo Jingsi, He Yuanmin, Xiao Liping, et al. Experimental study on the dynamic behavior of concrete-filled steel tube after exposure to high temperatures under multiple impact loadings[J]. Journal of Hunan University (Natural Sciences), 2012, 39(9):6-10. doi: 10.3969/j.issn.1674-2974.2012.09.002
    [10]
    钟善桐.钢管混凝土结构[M].3版.北京:清华大学出版社, 2003:231-268.
    [11]
    Bischoff P H, Perry S H. Compressive behaviour of concrete at high strain rates[J]. Materials & Structures, 1991, 24(6):425-450. doi: 10.1007/BF02472016
    [12]
    Davies E D H, Hunter S C. The dynamic compression testing of solids by the method of split Hopkinson pressure bar[J]. Journal of the Mechanics and Physics of Solids, 1963, 11(3):155-179. doi: 10.1016/0022-5096(63)90050-4
    [13]
    混凝土结构设计规范: GB50010-2002[S].北京: 中国建筑工业出版社, 2002: 13-15.
    [14]
    金属材料室温拉伸试验方法: GB/T228-2002[S].北京: 中国建筑工业出版社, 2002: 10-12.
    [15]
    王礼立.应力波基础[M].北京:国防工业出版社, 2010:5-35.
    [16]
    李志武, 许金余, 白二雷, 等.高温后混凝土SHPB试验研究[J].振动与冲击, 2012, 31(8):143-147. doi: 10.3969/j.issn.1000-3835.2012.08.028

    Li Zhiwu, Xu Jinyu, Bai Erlei, et al. SHPB test for post-high-temperature concrete[J]. Journal of Vibration and Shock, 2012, 31(8):143-147. doi: 10.3969/j.issn.1000-3835.2012.08.028
    [17]
    Song T Y. Concrete filled steel tube stub columns under combined temperature and loading[J]. Journal of Constructional Steel Research, 2010, 66(3):369-384. doi: 10.1016/j.jcsr.2009.10.010
    [18]
    林震宇, 吴炎海, 沈祖炎.圆钢管活性粉末混凝土轴压力学性能研究[J].建筑结构学报, 2005, 26(4):52-56. doi: 10.3321/j.issn:1000-6869.2005.04.008

    Lin Zhenyu, Wu Yanhai, Shen Zuyan. Research on behavior of RPC filled circular steel tube column subjected to axial compression[J]. Journal of Building Structures, 2005, 26(4):52-56. doi: 10.3321/j.issn:1000-6869.2005.04.008
    [19]
    李海艳.活性粉末混凝土高温爆裂及高温后力学性能研究[D].哈尔滨: 哈尔滨工业大学, 2012: 60, 96-97.
    [20]
    Comité Euro-International du Béton. Concrete structure under impact and impulsive loading: CEB Bulletin No.187[R]. Lausanne Switzerland, 1988.
    [21]
    任晓虎, 霍静思, 陈柏生.高温后钢管混凝土短柱落锤动态冲击试验研究[J].振动与冲击, 2011, 30(11):67-73. doi: 10.3969/j.issn.1000-3835.2011.11.015

    Ren Xiaohu, Huo Jingsi, Chen Baisheng. Dynamic behaviors of concrete-filled steel stub columns after exposure to high temperature[J]. Journal of Vibration and Shock, 2011, 30(11):67-73. doi: 10.3969/j.issn.1000-3835.2011.11.015
    [22]
    Xiao Yan, Shan Jianhua, Zheng Qiu, et al. Experimental studies on concrete filled steel tubes under high strain rate loading[J]. Journal of Materials in Civil Engineering, 2009, 21(10):569-577. doi: 10.1061/(ASCE)0899-1561(2009)21:10(569)
    [23]
    Jones N. Structural impact[M]. Cambridge, New York: Cambridge University Press, 1988:100-150.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(13)  / Tables(3)

    Article Metrics

    Article views (4153) PDF downloads(525) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return