Volume 43 Issue 10
Oct.  2023
Turn off MathJax
Article Contents
ZHAO Yijia, WANG Rui, ZHAO Hui, MAO Min, SHEN Linghua. Impact resistances of FRP-concrete-steel double skin tubular columns and their mechanism analyses[J]. Explosion And Shock Waves, 2023, 43(10): 103101. doi: 10.11883/bzycj-2022-0335
Citation: ZHAO Yijia, WANG Rui, ZHAO Hui, MAO Min, SHEN Linghua. Impact resistances of FRP-concrete-steel double skin tubular columns and their mechanism analyses[J]. Explosion And Shock Waves, 2023, 43(10): 103101. doi: 10.11883/bzycj-2022-0335

Impact resistances of FRP-concrete-steel double skin tubular columns and their mechanism analyses

doi: 10.11883/bzycj-2022-0335
  • Received Date: 2022-08-07
  • Rev Recd Date: 2022-12-27
  • Publish Date: 2023-10-27
  • FRP-concrete-steel double skin tubular columns (FRP-DSTCs) consist of an outer FRP tube and an inner steel tube, with the space between them infilled by concrete. This type of members has been applied in bridge piers, and the impact resistance is an important index for its utilization. Therefore, based on the previous test, the finite element analysis (FEA) models considering the coupling of axial and impact loads are established using ABAQUS software and verified by comparing the simulation and test results. In the model, the static implicit and dynamic explicit analysis are coupled by using Restart and Import commands. In addition, the strain rate effect of the steel and concrete are considered. Firstly, the mechanism of impact resistance under coupling axial and impact loads is analyzed. Then, the influence of thickness and fiber orientations of FRP, axial-load ratio, impact velocity, hollow ratio, diameter-to-thickness ratio of the steel tube and material strengths on the impact resistance are investigated. Finally, the formula used to predict the dynamic increase factor of the plateau impact force under coupling axial and impact loads is suggested. Results indicate that the deformation pattern of FRP-DSTCs mainly presents flexural deformation, and the plastic deformation of concrete is the main energy dissipation mechanism of such members. The outer FRP can significantly improve the lateral impact resistance of the specimen, and increasing the number of FRP layers leads to enhanced impact resistance. In addition, the axial load has an obvious effect on the impact resistance, and the effect is negative when the axial load ratio exceeds 0.7. The diameter-to-thickness ratio of steel tube presents marginal effects on the impact resistance. The proposed formula that considers the hollow ratio, strengths of concrete and inner steel tube, thickness of FRP, axial load ratio and impact velocity can reasonably predict the impact bearing capacity of FRP-DSTCs.
  • loading
  • [1]
    YU T, WONG Y L, TENG J G, et al. Flexural behavior of hybrid FRP-concrete-steel double-skin tubular members [J]. Journal of Composites for Construction, 2006, 10(5): 443–452. DOI: 10.1061/(ASCE)1090-0268(2006)10:5(443).
    [2]
    BAILEY C G, YAQUB M. Seismic strengthening of shear critical post-heated circular concrete columns wrapped with FRP composite jackets [J]. Composite Structures, 2012, 94(3): 851–864. DOI: 10.1016/j.compstruct.2011.09.004.
    [3]
    陈光明, 陆奕辰, 谢攀, 等. FRP-混凝土-钢双壁空心桥墩分析及设计方法研究 [J]. 中国公路学报, 2022, 35(2): 12–38. DOI: 10.19721/j.cnki.1001-7372.2022.02.002.

    CHEN G M, LU Y C, XIE P, et al. Analysis and design methods for FRP-concrete-steel double-skin tubular bridge piers [J]. China Journal of Highway and Transport, 2022, 35(2): 12–38. DOI: 10.19721/j.cnki.1001-7372.2022.02.002.
    [4]
    ABDELKARIM O I, ELGAWADY M A. Analytical and finite-element modeling of FRP-concrete-steel double-skin tubular columns [J]. Journal of Bridge Engineering, 2015, 20(8): B4014005. DOI: 10.1061/(ASCE)BE.1943-5592.0000700.
    [5]
    LI P D, ZHOU Y W, YANG T Q, et al. Axial compressive behavior of seawater sea-sand recycled aggregate concrete-filled double-skin non-corrosive tubular columns with square cross-section [J]. Thin-Walled Structures, 2021, 167: 108213. DOI: 10.1016/j.tws.2021.108213.
    [6]
    HAN L H, HOU C C, ZHAO X L, et al. Behaviour of high-strength concrete filled steel tubes under transverse impact loading [J]. Journal of Constructional Steel Research, 2014, 92: 25–39. DOI: 10.1016/j.jcsr.2013.09.003.
    [7]
    陈林. 桥墩防车辆撞击研究 [D]. 长沙: 湖南大学, 2015.

    CHEN L. Research on bridge piers subjected to vehicle collisions [D]. Changsha, Hunan, China: Hunan University, 2015.
    [8]
    DEMARTINO C, WU J G, XIAO Y. Experimental and numerical study on the behavior of circular RC columns under impact loading [J]. Procedia Engineering, 2017, 199: 2457–2462. DOI: 10.1016/j.proeng.2017.09.386.
    [9]
    LI R W, ZHOU D Y, WU H. Experimental and numerical study on impact resistance of RC bridge piers under lateral impact loading [J]. Engineering Failure Analysis, 2020, 109: 104319. DOI: 10.1016/j.engfailanal.2019.104319.
    [10]
    LIU B, FAN W, GUO W, et al. Experimental investigation and improved FE modeling of axially-loaded circular RC columns under lateral impact loading [J]. Engineering Structures, 2017, 152: 619–642. DOI: 10.1016/j.engstruct.2017.09.009.
    [11]
    杨晓强. 结构钢动态本构模型与方形高强CFST构件抗侧向冲击性能 [D]. 哈尔滨: 哈尔滨工业大学, 2020. DOI: 10.27061/d.cnki.ghgdu.2020.001560.

    YANG X Q. Dynamic constitutive models of structural steels and transverse impact resistance of high-strength concrete filled steel tubes with square cross-section [D]. Harbin, Heilongjiang, China: Harbin Institute of Technology, 2020. DOI: 10.27061/d.cnki.ghgdu.2020.001560.
    [12]
    WANG R, HAN L H, TAO Z. Behavior of FRP-concrete-steel double skin tubular members under lateral impact: experimental study [J]. Thin-Walled Structures, 2015, 95: 363–373. DOI: 10.1016/j.tws.2015.06.022.
    [13]
    CHEN Z L, WANG J, CHEN J Y, et al. Responses of concrete-filled FRP tubular and concrete-filled FRP-steel double skin tubular columns under horizontal impact [J]. Thin-Walled Structures, 2020, 155: 106941. DOI: 10.1016/j.tws.2020.106941.
    [14]
    LIN G, TENG J G. Three-dimensional finite-element analysis of FRP-confined circular concrete columns under eccentric loading [J]. Journal of Composites for Construction, 2017, 21(4): 04017003. DOI: 10.1061/(ASCE)CC.1943-5614.0000772.
    [15]
    纪孙航, 王文达, 鲜威. CFRP加固火灾作用后圆钢管混凝土构件的侧向撞击性能研究 [J]. 工程力学, 2021, 38(8): 178–191. DOI: 10.6052/j.issn.1000-4750.2020.08.0586.

    JI S H, WANG W D, XIAN W. Lateral impact behavior of CFRP-reinforced circular concrete-filled steel tubular members after exposure to fire [J]. Engineering Mechanics, 2021, 38(8): 178–191. DOI: 10.6052/j.issn.1000-4750.2020.08.0586.
    [16]
    AL-ZUBAIDY H, ZHAO X L, AL-MAHAIDI R. Mechanical characterisation of the dynamic tensile properties of CFRP sheet and adhesive at medium strain rates [J]. Composite Structures, 2013, 96: 153–164. DOI: 10.1016/j.compstruct.2012.09.032.
    [17]
    BENTZ E C, FOSTER S J, FERNÁNDEZ RUIZ M, et al. Model code 2010- First complete draft, Chapters 7.3 and 7.13 [S]. Lausanne, Switzerland: Fédération Internationale du Béton, 2010.
    [18]
    LAM L, TENG J G. Design-oriented stress-strain model for FRP-confined concrete [J]. Construction and Building Materials, 2003, 17(6/7): 471–489. DOI: 10.1016/S0950-0618(03)00045-X.
    [19]
    HAN L H, YAO G H, TAO Z. Performance of concrete-filled thin-walled steel tubes under pure torsion [J]. Thin-Walled Structures, 2007, 45(1): 24–36. DOI: 10.1016/j.tws.2007.01.008.
    [20]
    ABRAMOWICZ W, JONES N. Dynamic axial crushing of square tubes [J]. International Journal of Impact Engineering, 1984, 2(2): 179–208. DOI: 10.1016/0734-743X(84)90005-8.
    [21]
    韩林海. 钢管混凝土结构: 理论与实践 [M]. 2版. 北京: 科学出版社, 2007: 810–811.
    [22]
    YANG T, WANG W Q, LIU Z X, et al. Behavior of CFRP-UHPFRC-steel double skin tubular columns against low-velocity impact [J]. Composite Structures, 2021, 261: 113284. DOI: 10.1016/j.compstruct.2020.113284.
    [23]
    中国土木工程学会. 中空夹层钢管混凝土结构技术规程: T/CCES 7—2020 [S]. 北京: 中国建筑工业出版社, 2020.

    China Civil Engineering Society. Technical specification for concrete-filled double skin steel tubular structures: T/CCES 7—2020 [S]. Beijing, China: China Architecture and Building Press, 2020.
    [24]
    中华人民共和国住房和城乡建设部, 国家市场监督管理总局. 纤维增强复合材料工程应用技术标准: GB 50608—2020 [S]. 北京: 中国计划出版社, 2020.

    Ministry of Housing and Urban-Rural Development of the People’s Republic of China, State Administration for Market Regulation. Technical standard for fiber reinforced polymer (FRP) in construction: GB 50608—2020 [S]. Beijing, China: China Planning Press, 2020.
    [25]
    HAN L H, TAO Z, LIAO F Y, et al. Tests on cyclic performance of FRP-concrete-steel double-skin tubular columns [J]. Thin-Walled Structures, 2010, 48(6): 430–439. DOI: 10.1016/j.tws.2010.01.007.
    [26]
    王罡, 胡清, 刘昌永, 等. FRP缠绕方式对FRP约束钢管混凝土短柱轴压性能的影响研究 [J]. 建筑结构学报, 2021, 42(S2): 189–196. DOI: 10.14006/j.jzjgxb.2021.S2.0022.

    WANG G, HU Q, LIU C Y, et al. Axial compressive behavior of FRP confined concrete-filled steel tubular columns with different FRP-sheet winding patterns [J]. Journal of Building Structures, 2021, 42(S2): 189–196. DOI: 10.14006/j.jzjgxb.2021.S2.0022.
    [27]
    刘明学, 钱稼茹. FRP-混凝土-钢双壁空心管的截面弯矩-曲率全曲线 [J]. 清华大学学报(自然科学版), 2007, 47(12): 2105–2110. DOI: 10.16511/j.cnki.qhdxxb.2007.12.020.

    LIU M X, QIAN J R. Moment-curvature relationships of FRP-concrete-steel double-skin tubular members [J]. Journal of Tsinghua University (Science and Technology), 2007, 47(12): 2105–2110. DOI: 10.16511/j.cnki.qhdxxb.2007.12.020.
    [28]
    GUO Q Q, ZHAO W Y. Displacement response analysis of steel-concrete composite panels subjected to impact loadings [J]. International Journal of Impact Engineering, 2019, 131: 272–281. DOI: 10.1016/j.ijimpeng.2019.05.022.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(18)  / Tables(2)

    Article Metrics

    Article views (318) PDF downloads(118) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return